EasyManua.ls Logo

Endress+Hauser Micropilot FMR53 - Measuring Conditions

Endress+Hauser Micropilot FMR53
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR53, FMR54 HART Installation
Endress+Hauser 19
6.1.6 Beam angle
a
D
W
a
D
_
=
2
2
. .
tan
W
A0016891
 4 Relationship between beam angle α, distance D and beamwidth diameter W
The beam angle is defined as the angle α where the energy density of the radar waves reaches
half the value of the maximum energy density (3-dB-width). Microwaves are also emitted
outside the signal beam and can be reflected off interfering installations.
Beam diameter W as a function of beam angle α and measuring distance D:
FMR53
Beam angle α 23°
Measuring distance (D) Beamwidth diameter W
3 m (9.8 ft) 1.22 m (4 ft)
6 m (20 ft) 2.44 m (8 ft)
9 m (30 ft) 3.66 m (12 ft)
12 m (39 ft) 4.88 m (16 ft)
15 m (49 ft) 6.1 m (20 ft)
20 m (66 ft) 8.14 m (27 ft)

Other manuals for Endress+Hauser Micropilot FMR53