Loading...
Oil Leak Detector NAR 300 system
Endress+Hauser 39
11 Accessory
11.1 Float guide
Note!
When mounting the float guide weight, set it up horizontally. Remove trash and stones on the pit
bottom before mounting the Float Sensor. The length of float guide is 2m (standard), but if you need
anything else, please order as special version.
11.2 U bolt and Cable gland
U bolt (JIS F3022 B50) is used for mounting the transmitter. Please prepare a pipe of nominal 50A
(2B Φ60.5 mm).
Tighten and fix the cable gland after insert a cable from the float sensor NAR 300.
200
350
280
200
10
L
10
Name
Float guide
2
SS400
SUS304
1
SUS304
6
SUS304
M10 nut
Float guide
Weight
Weight
M10 nut
Delivery
quantity
Material
(JIS F3022 B50)
Name
Delivery
quantity
2
1
4
4
U bolt
Material
Mounting U bolt
Accessory : Nut
: Washer
Cable gland
Cable gland
Carbon steel
(chromate)
Nylon
11 Accessory

Related product manuals