Wiring
12
4 Wiring
4.1 Wiring examples
L00-NXA82xxx-02-00-00-en-005
4.2 Terminal assignment
L00-NXA82xxx-04-00-00-yy-020
A: Power supply B: Fuse C: Status relay D: System LAN port E: Sync Link LAN port F: Service LAN port
G: Endress+Hauser CDI port H: Display port I: USB port J: Weights & Measures locking switch
NXA820 NXA820
NXA822
NXA820
Tank Scanner
NXA820
Tank Scanner
NXA822
Host Link
Switch
Browser
Modbus
NXA820
NXA821
Data Concentrator
Bediener 1
Bediener 2
SPS
Feldbus-Protokoll
Feldbus-Protokoll
23
1
6
7
8
W&M
RESET
RESET
NXA Status
Relay
E
L+
L-
6
7
8
3
2
1
Fuse
POWER
10,5 ... 32V DC
2AT
A
B
C
D
E
F
G H
I
J