Tankvision configuration
39
PC assignment
Tankvision Tank Scanner - PC Assignment
Every PC to be connected to the sealed system has to be registered. The PCs are registered under
"System ➝ Global Settings ➝ W&M Seal ➝ Access Configuration".
The registered devices are listed with their MAC address in the column on the left. The MAC
address of the PC currently used is displayed in the column on the right.
Each PC has to be registered individually on every Tankvision box. If no PC is registered in the
system, an error message is shown on the display of the Tankvision box once the W+M switch has
been flipped.
L00-NXA820xx-07-00-00-xx-001
Error Message - No PC Registered in the System
During calibration acceptance, the list must be checked to ensure it only contains the MAC
addresses of the Tankvision boxes and the PCs that should access the system. The PCs can be
checked, for example, by loading the page above from every PC that should have access to the
system and then comparing the MAC addresses (Registered Systems against Current MAC Address).
The MAC addresses of the Tankvision box are provided on the nameplate.
NXA
NXA820_A30016011
INFO
Access Configuration Er
F317:
0.0.0.002/12/2009
172.0.0.1 02:51:54 PM