F1.1 Battery capacity. Your Main battery’s capacity in Amphours (Ah).
Default: 200Ah Range: 10 – 10000Ah Step size: variable
F1.2 Nominal discharge rate (C-rating). The discharge rate (in hours) at which the battery
manufacturer rates your battery’s capacity.
Default: 20h Range: 1 – 20h Step size: 1h
F1.3
Nominal temperature. The temperature at which the battery manufacturer rates
your battery’s capacity.
Default: 20°C Range: 0 – 40°C Step size: 1°C
F1.4
Peukert’s exponent. Peukert’s exponent represents the e ect of reducing battery
capacity at higher discharge rates. When the Peukert value of your battery is unknown,
it is recommended to keep this value at 1.17. A value of 1.00 disables the Peukert
compensation and should be used for Lithium based batteries.
Default: 1.17 Range: 1.00 – 1.50 Step size: 0.01
F1.5 Reserved.
Default: - Range: - Step size: -
F1.6
Battery temperature. In this Function the average battery temperature can be adjusted
when no temperature sensor is connected. When a temperature sensor is connected,
the temperature readout in the Normal Operating Mode is enabled.
Default: 20°C Range: -20°C – 50°C Step size: 1°C
F1.7
Battery bank 1 name. Choose a display name for your battery bank that comes nearest
to your application.
Default: MAIN Range: see table 8
Table 8
Battery bank name Description
Bank 1 Battery bank 1
Bank 2 Battery bank 2
Bank 3 Battery bank 3
Main Main battery bank