EasyManua.ls Logo

Enerdrive ePro Plus - Technical Specifications

Enerdrive ePro Plus
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.enerdrive.com.au Page 35
10. TECHNICAL SPECIFICATIONS
Parameter ePRO Plus
Supply voltage range 7..70Vdc
Supply current (@ 12V/ 24V/48V) 10mA / 6mA / 5mA
Input voltage range main battery (+B1) 7..70Vdc
Input voltage range second and third battery (+B2, +B3) 1..70Vdc
Input current range -600..+600A
Battery capacity range 10..10000Ah
Operating temperature range -20..+5C
Storage temperature range -30..+70°C
Readout resolution Voltage (0..70V)
Current (0..10A)
Current (10..100A)
Current (100..600A)
State of Charge (0..100%)
Time remaining (0..24hrs)
Time remaining (24..240hrs)
Amphours (0..10000Ah)
Power (0..42kW)
Temperature (-20°C..+50°C)
± 0.01V
± 0.01A
± 0.1A
± 1A
± 1%
± 1min
± 1hr
± 0.01Ah..10Ah (variable)
± 0.01W..1kW (variable)
± 0.5°C
Voltage measurement accuracy ± 0.3%
Cu
rrent measurement accuracy ± 0.4%
Shunt dimensions: Footprint
Base height
Total height
Weight
100 x 100mm
24.0mm
64.5mm
290grams
Display dimensions: Front panel
Body diameter
Total depth
Weight
Ø 64.0mm
Ø 51.5mm
36.0mm
70grams
Protection class IP20 (CDU front panel only
IP65)

Other manuals for Enerdrive ePro Plus