Enerdrive ePRO Plus Battery Monitor Owners Manual (Rev. 1.03)Page 30
A12
Temperature averaging lter. Speci es the noise lter setting at the temperature
sensor input. The default value of 1 will be ne for most applications. Only in case
of long temperature sensor cables and/or environments with extremely high RF
interference levels, it is advised to set this value to 2.
Default: 1 Range: 0 – 2 Step size: 1
All changed Function settings remain in the ePRO Plus’s internal memory. Even when
the supply voltage has been interrupted. This also applies to the stored Status and
History items.