Enerdrive ePRO Plus Battery Monitor Owners Manual (Rev. 1.03)Page 42
Since there are too many variables involved, Enerdrive assumes no responsibility or
liability for battery damage or costs which might arise out of the use of the midpoint
voltage alarm. This functionality should only be used by experienced installers with
su
cient battery knowledge and is intended for global indication purposes only.
d = 100 *
(V2-V1)
Vavg
where:
d = deviation in %
V2 = voltage of the upper half in the series string
V1 = voltage of the lower half in the series string
Vavg =
(V1+V2)
2