1.0 IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. Shipping
damage is not covered by warranty. If shipping damage is found,
notify carrier at once. The carrier is responsible for all repair and
replacement costs resulting from damage in shipment.
SAFETY FIRST
2.0 SAFETY ISSUES
Read all instructions, warnings and cautions carefully.
Follow all safety precautions to avoid personal injury or
property damage during system operation. Enerpac
cannot be responsible for damage or injury resulting
from unsafe product use, lack of maintenance or incorrect product
and/or system operation. Contact Enerpac when in doubt as to the
safety precautions and operations. If you have never been trained on
high-pressure hydraulic safety, consult your distribution or service
center for a free Enerpac Hydraulic safety course.
Failure to comply with the following cautions and warnings could
cause equipment damage and personal injury.
A CAUTION is used to indicate correct operating or maintenance
procedures and practices to prevent damage to, or destruction of
equipment or other property.
A WARNING indicates a potential danger that requires correct
procedures or practices to avoid personal injury.
A DANGER is only used when your action or lack of action may
cause serious injury or even death.
WARNING: Wear proper personal protective gear when
operating hydraulic equipment.
WARNING: Stay clear of loads supported by hydraulics.
A cylinder, when used as a load lifting device, should
never be used as a load holding device. After the load
has been raised or lowered, it must always be blocked
mechanically.
WARNING: USE ONLY RIGID PIECES TO HOLD LOADS.
Carefully select steel or wood blocks that are capable of
supporting the load. Never use a hydraulic cylinder as a
shim or spacer in any lifting or pressing application.
DANGER: To avoid personal injury keep hands and
feet away from cylinder and workpiece during
operation.
WARNING: Do not exceed equipment ratings. Never
attempt to lift a load weighing more than the capacity of
the cylinder. Overloading causes equipment failure and
possible personal injury. The cylinders are designed for a max.
pressure of 10,000 psi (700 bar). Do not connect a jack or cylinder
to a pump with a higher pressure rating.
Never set the relief valve to a higher pressure than the
maximum rated pressure of the pump. Higher settings
may result in equipment damage and/or personal injury.
WARNING: The system operating pressure must not
exceed the pressure rating of the lowest rated
component in the system. Install pressure gauges in the
system to monitor operating pressure. It is your window
to what is happening in the system.
CAUTION: Avoid damaging hydraulic hose. Avoid sharp
bends and kinks when routing hydraulic hoses. Using a
bent or kinked hose will cause severe back-pressure.
Sharp bends and kinks will internally damage the hose leading
to premature hose failure.
Do not drop heavy objects on hose. A sharp impact
may cause internal damage to hose wire strands.
Applying pressure to a damaged hose may cause it to
rupture.
IMPORTANT: Do not lift hydraulic equipment by the
hoses or swivel couplers. Use the carrying handle or
other means of safe transport.
CAUTION: Keep hydraulic equipment away from
flames and heat. Excessive heat will soften packings
and seals, resulting in fluid leaks. Heat also weakens
hose materials and packings. For optimum performance do not
expose equipment to temperatures of 150 °F (65 °C) or higher.
Protect hoses and cylinders from weld spatter.
®
®
®
Instruction Sheet
GPE Series
Global Electric Pumps
L2461 Rev. C 11/03
Index:
English: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Français: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12
Deutsch: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-18
Italiano: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-24
Español: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-30
Nederlands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-36
Portuguese . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37-42
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43-48
Svenska: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49-54
GPS30-50

Questions and Answers

  • M
    michealbauerAug 10, 2025
    Why does my Enerpac GPE Water Pump build less than full pressure?
    • K
      Katherine ButlerAug 10, 2025
      If your Enerpac Water Pump builds less than full pressure, it could be due to several reasons: the relief valve might be set too low, there could be an external system leak, or there might be an internal leak in the pump, valve, or another system component.
  • J
    John RodgersAug 15, 2025
    Why does the cylinder drift back on its own with Enerpac GPE Water Pump?
    • K
      Kathryn RobinsonAug 15, 2025
      If the cylinder drifts back on its own when using an Enerpac Water Pump, this may be due to an external system leak or an internal leak in a system component.
  • P
    philipmcdonaldAug 19, 2025
    Why does the Enerpac GPE Water Pump motor stall under load?
    • K
      kimberlydiazAug 20, 2025
      If the Enerpac Water Pump motor stalls under load, it could be due to low voltage.
  • K
    kimberly44Aug 26, 2025
    What causes a single-acting cylinder not to return on Enerpac Water Pump?
    • N
      Nicholas KellyAug 26, 2025
      If a single-acting cylinder will not return when using an Enerpac Water Pump, it could be due to a valve malfunction, a broken cylinder return spring, restricted or blocked return flow, or no load on a "load return" cylinder.
  • J
    Joshua RodriguezAug 30, 2025
    What causes a double-acting cylinder not to return with Enerpac GPE Water Pump?
    • H
      Hayley LozanoAug 30, 2025
      If a double-acting cylinder will not return when using an Enerpac Water Pump, it could be due to a valve malfunction, or a return flow that is restricted or blocked.
  • M
    michaelmeadowsSep 3, 2025
    Why will the electric valve not operate on my Enerpac Water Pump?
    • B
      brandon26Sep 4, 2025
      If the electric valve on your Enerpac Water Pump will not operate, it could be due to no power, the wrong voltage, or the valve being out of adjustment.

Enerpac GPE Series Specifications