90
Settings
Most submenus in the Settings
menu are read only menus.
Their function is to show which
settings have been selected for
your ventilation system.
You can make changes in the following menus, if
necessary:
Menu Description of change
Screen settings - Changing language, date, time,
brightness, and other screen properties.
Heat recovery
settings
- Heat recovery anti-freezing start and
shutdown.
The technician has congured the rest of
the heat recovery anti-freezing settings.
Summer night
cooling
- Turning the summer night cooling on and
o.
- Setting the dates and times for summer
night cooling.
- Preventing or allowing active cooling.
Summer night cooling is an ecient way
to cool indoor air. Summer night cooling
activates at night and brings in cool
night air, which in turn lowers the indoor
temperature.
The installer has congured the other
summer night cooling settings.
Boost functions - Start and shutdown of humidity, carbon
dioxide, and temperature boost
Other values are not editable.
Menu Description of change
Usage mode
settings
- Setting the boost time in the Manual
boost settings.
- Setting the overpressure time in the
Manual overpressure settings.
- Activating and deactivating Silent mode.
- setting the duration of the Silent mode
When the Silent mode is activated, the
mode symbol appears in the mode menu
on the main page (behind the green circle).
- Activating and de-activating the
Maximum heating/cooling mode in the
Maximum heating/cooling settings menu.
The technician has congured most Mode
settings when installing the unit.
Alarm settings - Changing the alarm or maintenance
notication for changing lters.
- Resetting the alarm or maintenance
notication for changing lters.
By setting the times and dates for alarms
in the Alarms menu, you can decide when
to receive B alarms. B alarms do not require
immediate action.
- Activating and de-activating the lter
pressure guard.
If your unit has installed lter guards (very
rare in detached houses), you can activate
and de-activate them in the Alarms
settings menu.
Only trained ventilation technicians can change