Status Icons
The Status Icons are color-coded and light up when communicating to the operator. Pay close
attention to any Status Icon and its color that may appear.
Status Icon
Description
Check EngineYellow icon is visible if the controller receives a DM1 (Active
Diagnostic Trouble Code) message with an amber lamp command, the
yellow Icon displays
Check EngineRed icon is visible if the controller receives a DM1 message
with a red lamp command, the red icon displays
Parking Break SwitchGreen Icon displays when the parking brake is
applied
Transmission NeutralGreen icon displays when the transmission is in
neutral
Engine Exhaust High Temperature LampRed icon displays during active
DPF regeneration when the DPF outlet temperature is greater than 450°C
and post engine fuel injection is occurring.
Diesel Particulate Filter Lamp CommandRed icon is: (1) On solid during
regeneration (2) Blinking to request parked regeneration. Yellow Icon is on
solid to request automatic active regeneration when regeneration is inhibited
DPF Regeneration set to Inhibit—Displays when the machine or the operator
has inhibited Regeneration
Glossary of Terms and Acronyms
CAN Controller Area Network
DM1 Diagnostic Message 1, Active Diagnostic Trouble Codes
DM2 Diagnostic Message 2, Previously Active Diagnostic Trouble Codes
DM3 Diagnostic Message 3, Diagnostic Data Clear/Reset for Previously Active DTCs
DM4 Freeze Frame Parameters
DPF Diesel Particulate Filter
DTC Diagnostic Trouble Code
ECU Engine Control Unit
FMI Failure Mode Identifier
PGN Parameter Group Number
SPN Suspect Parameter Number