Enraf-Nonius B.V. Curapuls 670 Service Manual 1403773
Introduction June 19971-4
product, a detailed description of the problem, the number of the same problems,
quantity of sold equipment and your solution to the problem (if any). The product
complaint report can be found as an enclosure in the Service Reference book.
1.1.9 Additional Information
Please do not hesitate to contact your National sales organisation or distributor.
For additional information:
Enraf-Nonius B.V.
P.O. Box 810
2600 AV Delft
The Netherlands
Tel: +31 (0)15 - 2698400
Fax: +31 (0)15 - 2561686 (Sales Division International)
Technical service support:
Tel: +31 (0)45 - 5276220
Fax: +31 (0)45 - 5259662
E-mail: tss@enraf-nonius.nl
1.2 GENERAL
The Curapuls 670 is a two channel microprocessor-controlled unit for pulsed shortwave
therapy, applied by means of one or two inductive electrodes (Circuplode).
In the Curapuls 670, pulse duration, pulse frequency, power and treatment duration are
adjustable. When two electrodes are used, the selected pulse frequency and treatment
duration apply to both electrodes, while the other parameters can be set separately for
each electrode.
Simple and safe operation
The various parameters are selected by means of push buttons, and are set using one
central control knob. Each parameter is shown on a LCD display, giving a good
overview of the selected parameters. This is made possible by the application of
microprocessor technology. The microprocessor controls and monitors all functions
during operation. Directly after switching on, the microprocessor automatically tests the
electronics of the Curapuls 670 for safety and correct functioning.
The Curapuls 670 menu can be set in five languages, GB, NL, D, F, E. Changing
languages can be done by pressing the cursor left key for approx. 2 sec. in the main
menu. Changing the language (and other default settings) is done by selecting the
option with the cursor UP or DOWN keys and rotating the central control.
Pre programmed treatment protocols are available. The treatment protocols are divided
in seven sub-selections. In the sub-selection a treatment can be chosen from a list of
protocols.

Other manuals for Enraf Nonius Curapuls 670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enraf Nonius Curapuls 670 and is the answer not in the manual?

Enraf Nonius Curapuls 670 Specifications

General IconGeneral
BrandEnraf Nonius
ModelCurapuls 670
CategoryMedical Equipment
LanguageEnglish

Related product manuals