ENGLISH
EN109-1435752-42 Page 17 of 29
[11] Power
The display shows the set power. Adjustment of the power is only possible if also a treatment time
has been set.
[12] Program number/protocol number
The number under which a certain parameter setting is stored. A program number from the protocol
memory is preceded by a letter for example A1. A program number from the “free” memory is
preceded by a symbol # for example #1. The Radarmed 950+ is delivered with an empty memory and
should be filled by the user.
[13] Radiator type
The display indicates the proposed radiator type.
R=Local field radiator
L=Longitudinal radiator
M=Large field radiator (Mulden electrode)
[14] Dosage
The display indicates the proposed dosage.
1=Imperceptible heat: Skin heated to just below the heat sensitivity.
2=Slide heating: Just perceptible warmth.
3=Comfortably warmth: Pleasant, easily-tolerable feeling of warmth.
4= Hot: Just tolerable, almost burning feeling of warmth.
For further information with regard to dosage we refer to the booklet “Treatment tables” with reference
number 1435.770.
[15] Adjustment in Watt
The display indicates the proposed power setting in Watt (minimal and maximal value).
[16] On/off switch
With this switch the Radarmed is turned on/off.
[17] Ventilation slots
These openings must be kept clear for ventilation.
[18] Connection points electrode arm
The electrode arm can be connected at choice at the left or
right side of the unit (see paragraph 8.6 of this manual).
[19] Hook for mains cable
Hook to hang up the mains cable when the unit is out of operation.
[20] HF-connection
Connection for the HF-cable (see paragraph 8.8 of this manual).
[21] Connection mains cable
Connect the Radarmed to a grounded safety socket of a voltage
corresponding to the data mentioned on the type plate of the unit.
[22] Connection for potential equalization cable
A special cable can be supplied for areas where local regulations
require connection of a potential equalization cable.
[23] Type plate
The type plate gives details of the model, series and serial number
(for service, warranty etc.) as well as ratings such as mains voltage
and power consumption.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enraf Nonius Radarmed 950+ and is the answer not in the manual?

Enraf Nonius Radarmed 950+ Specifications

General IconGeneral
BrandEnraf Nonius
ModelRadarmed 950+
CategoryMedical Equipment
LanguageEnglish

Related product manuals