Page 35
710245B
NOTE: When the EN1000 series controls are used for SEAM WELDING, RESISTANCE
BRAZING, or other high duty cycle applications, additional surge resistors must be
installed in accordance with instructions on the wiring diagram. These resistors may be
obtained through your resistance welder dealer or directly from ENTRON CONTROLS
INC.
If a control in which the resistors have been added is later used in a spot welding application,
it is not necessary to remove them.
6&+('8/(6(/(&7,21,17(51$/(;7(51$/DQG$17,7,('2:1
The default operation for the EXTENDED FUNCTION for SCHEDULE SELECT [SS] is
the INTERNAL Mode. In this Mode the schedule to be initiated will be determined by the
front panel selection of the desired schedule or use of TS1-FS3,FS7,FS11. TS1-FS3 results
in initiation of the displayed schedule, FS7 initiating SCHEDULE 10, FS11 initiating
SCHEDULE 20.
By use of EXTENDED FUNCTION [SS] one of four schedules can be selected by an
external device. TS1-FS3 is used to then initiate the selected schedule. See table 1
SCHEDULE SELECTS VS SCHEDULES.
TABLE 1 SCHEDULE SELECTS VS SCHEDULES
SS1
SS3
SCHEDULE
OPEN
OPEN
0
CLOSED
OPEN
10
OPEN
CLOSED
20
CLOSED
CLOSED
30
To program the control for EXTERNAL SCHEDULE operation, the EXTENDED
FUNCTION Mode [SS] must be selected. See section 7.3 EXTENDED FUNCTIONS. Use
the SCHEDULE SELECT Push Buttons (20 & 21) and SCHEDULE Display (22) to select
[SS]. With the control in the PROGRAM Mode enter a [01] into the DATA Display (4)
using DATA Push Buttons (5 & 6). As typical of other data entry the ENTER Push Button
(29) must be depressed to load the desired data.
To program the control for INTERNAL SCHEDULE operation (the default Mode), the
EXTENDED FUNCTION [SS] Mode must be selected. See section 7.3 EXTENDED
FUNCTIONS. Use the SCHEDULE SELECT Push Buttons (20 & 21) and SCHEDULE
Display (22) to select [SS]. With the control in the PROGRAM Mode enter a [00] into the
DATA Display (4) using DATA Push Buttons (5 & 6). As typical of other data entry the
ENTER Push Button (29) must be depressed to load the desired data.