Troubleshooting
9.The stove will not shut off.
Timer Control
w Check the connections to the 140°F (60°C) temperature sensor, start-up switch and the start-up timer
against the wiring diagram.
w Check the 140°F (60°C) temperature sensor by removing one of the brown wires from the sensor.
The unit should shut down right away as long as the start button was not pressed within 15 minutes
of this test. If the stove shuts down within fifteen (15) minutes, replace the 140°F (60°C) sensor. If
the stove does not shut down within fifteen (15) minutes, test the switch.
w To test the switch, the stove must be cold. Pull the plug, then plug the stove back in. If it fails to start,
replace the switch.
Circuit Board
ü If the unit will not shut off, ensure that the thermostat (if equipped) is turned down below the room
temperature (thermostat mode in the ON / OFF position).
ü If the unit is in the HI/LOW mode the unit will not shut off but will go to an idle setting (LOW). Press
the ON/OFF button to turn the unit off.
ü Disconnect one of the brown wires from the exhaust temperature sensor. If the unit continues to
operate, contact your local dealer for service.
10.The stove keeps going out
If the stove goes out and leaves fresh unburned pellets or cigarette-like ashes in the burn pot liner, the
fire is going out before the stove shuts off.
General
« Check to see that the Slider / Damper is in the correct position.
Timer Control
w Turn the Dial-a-Fire up slightly (poor quality pellets will require slightly higher settings).
Circuit Board
ü Turn the Heat Level up slightly (poor quality pellets will require slightly higher settings).
ü Set the auger trim till the #1 and #5 lights are illuminated.
If the stove goes out and there are partially burned pellets left in the burn pot liner, the stove has shut
down due to a lack of air, exhaust temperature, or power failure.
General
« Adjust the Slider / Damper.
« Check to see if the stove needs a more complete cleaning.
« Did the power go out?
« Contact your local Dealer for service.
Timer Control
w Turn the Dial-a-Fire up slightly (poor quality pellets will require slightly higher settings).
Circuit Board
ü Turn the Heat Level up slightly (poor quality pellets will require slightly higher settings).
If the stove goes out and there are no pellets in the liner, the auger is stopping.
General
« See “The auger motor will not function normally” and “The exhaust blower will not function
normally.

Table of Contents

Other manuals for Enviro EF3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enviro EF3 and is the answer not in the manual?

Enviro EF3 Specifications

General IconGeneral
BrandEnviro
ModelEF3
CategoryPellet stove
LanguageEnglish

Related product manuals