PIV & MIV
®
Loft Mounted Unit
INSTALLATION INSTRUCTIONS
IMPORTANT
Be sure to have read and understood these
instructions before beginning the installation
process.
Smoke Detectors
It is important that any open side of the plastic
diuser is not positioned within 1m of a smoke
detector. If the diuser cannot be repositioned,
up to two sides of the diuser may be closed
o using the plastic blanking plate supplied (Loft
only) so that the open sides face a minimum 1.5m
unobstructed path away from the detector. In 3
oor properties a metal re diuser should be
tted at minimum of 1m from the detector (see
page 8).
SAFETY AND RECOMMENDATIONS
All wiring must comply with Building
Regulations and the current I.E.E. Wiring
Regulations (BS7671) or the equivalent
standards for your country. The nal installation
should be examined and tested by a qualied
electrician.
Precautions must be taken to avoid the back-
ow of gases into the dwelling from the open
ue of gas or other fuel-burning appliances.
Make sure the mains supply complies with the
rating label for voltage, frequency and phase.
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made by
children without supervision.