12
in the room is lower than the selec-
ted level. In this case the extractor
continues to operate for the selected
period of time (over-run timer) after
the switch light has been switched off.
ATTENTION: When the humidity rate
is above the selected value, the auto-
matic option takes precedence over
the manual and the unit cannot then
be switched off using the pullcord.
Start-up timer function:
In this operation, the “start-up timer
function” allows to delay the extractor
start-up for a period of 50 seconds.
So that, for example, the fan does not
switch on if the usage time of the ba-
throom is less than 50s.
If you exceed the 50s and the humidity
level in the room is below the selected
level, the fan switches on, and when
the light switches off, runs the time
set by the timer.
This function is selected with the dip-
switch 8.
Factory settings:
Interval function: OFF
Interval time: 4h
• Humidistat: 60%HR
Timer: 1 minute
Start-up timer function: OFF
SILENT P DESIGN
Models provided with on/off pullcord
switch use the following wiring dia-
gram:
Fig.11: Fan operating only with pull-
cord.
MAINTENANCE
Fan equipment should be electrically
isolated and locked out before any
work starts.
The extractor fan only requires perio-
dical cleaning using a cloth lightly im-
pregnated with a soft detergent.
PUTTING OUT OF SERVICE
AND RECYCLING
EEC legislation and our con-
sideration of future gener-
ations mean that we should
always recycle materials
where possible; please do not
forget to deposit all packaging in the
appropriate recycling bins. If your de-
vice is also labeled with this symbol,
please take it to the nearest Waste
Management Plant at the end of its
serviceable life.
AFTER SALES SERVICE
We recommend you not to try to dis-
mantle or remove any other parts
than those mentioned as any tamper-
ing would automatically cancel the
EnviroVent guarantee.
If you detect any fault, contact our
dedicated Technical team on 01423
810810.