2.2 Important Installation Information
Characteristics of power supply input
Permanently connected to 230V AC supply
Characteristics of power supply output
Supplies 230V AC to the vehicle
Normal environmental conditions
Can be installed indoors or outdoors
Access requirements
Can be installed with no access restrictions
Mounting method
Stationary equipment intended for surface or post mounting
Protection against electric shock
Class II equipment
Charging mode
Mode 3 charging equipment. Note - Adaptors and conversion
adaptors sets are not allowed to be used with the equipment.
Cord extension sets are not allowed to be used.
Ventilation during supply of energy
Does not support ventilation during charging
The installer must select the RCD and earthing configuration in accordance with local regulation & best practice.
Where the EO Mini Pro includes DC leakage protection a Type A RCD can be fitted at the supply. Otherwise a Type B
RCD or equivalent should be used. EO recommend a 20A supply rated supply circuit for a 16A charging station and
40A supply for on 32A charging station.