GB
Electrical connections
Attention!
The electrical installation may be only car-
ried out by a registered electrical contrac-
tor, while adhering to the EU, national and
local directives for electric installations.
Connection of IR radiators
Mount the IR radiator according to the mount-
ing instructions supplied with IR radiator.
EOS IR radiators include connecting cable with
the Wieland type plug (female).
The output cable line of the control unit includes
the female plug and corresponding plug adap-
tor to connect up to 5 lines to IR radiators. To
connect the line:
• Unscrew the two screws of the clamped cov-
ering for connecting the cable with the plug
adaptor. Insert the plug into the free socket
of the plug adaptor and retighten the two
screws.
• The covering secures the plug connection
and prevents the accidental disconnection
of the joint.
See illustration on the right for details of con-
necting the cable line to the plug adaptor.
screws
clamped covering
plug adaptor
181 mm
126 mm
190 mm
135 mm
• After tting the cables insert the control unit
into the prepared rectangular opening.
• Attach the housing to the cabin wall by using
the 4 included fastening screws
• Next, we suggest that the cable be laid be-
hind a node board. If a IR radiator has also
been installed in this node board, it must be
located below the control unit.
IR control
Node board
IR radiator
Attention! Because of the higher start-
ing current by certain IR radiator types the
unit has to be fused by a 16A circuit breaker
with K characteristic (slow reacting fuse).