30
TPV 7 (SAMSUNG Protocol):
This accepts 4 commands:
TPV Scale
W<CR>
Weight: returns the weight with units and the scale's status:
<LF><PP.PPP><UU><CR><LF><'S'hh><CR><ETX>
TPV Scale
S<CR>
Scale status:
<LF><'S'hh><CR><ETX>
TPV Scale
Z<CR>
Returns the scale's status after performing an autozero:
<LF><'S'hh><CR><ETX>
TPV Scale
H<CR>
Weight in high resolution: returns the scale's status:
<LF><'S'hh><CR><ETX>
TPV Scale
Others
Unrecognized command:
<LF>?<CR><ETX>
ETX - Character (0x03, 3d).
LF - Character 0x0a, 10d.
CR - Character (0x0d, 13d).
PP.PPP - Value of the weight with decimal point and left-
justified with zeros (0x30).
UU - Measuring units in upper case (kg, oz, lb...).
'S'hh - Character 'S' + 2 status bytes.
? - Character 0x3F.