EasyManua.ls Logo

Epever MT52 - Page 23

Epever MT52
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
1) Batt. Type
Supported battery types are shown as below.
1
Lead–acid
battery
Sealed (default)
Gel
Flooded
2
Lithium
battery
LiFePO4 (LFP4S, LFP8S, LFP15S, LFP16S)
Li(NiCoMn)O2 (LNCM3S, LNCM6S, LNCM7S,
LNCM13S, LNCM14S)
3
User define
The battery type will display LiFePO4 15S/16S and Li(NiCoMn)O2 13S/14S only
when the controller connected to the MT52 supports 48V system voltage.
When modifying the battery type to "USE," the default voltage point is the
corresponding voltage before the battery type is modified.
2) Parameters of the Batt. AH, Temp Comp. Coeff and Rated Voltage
Parameter
Default
Range
Batt. AH (Battery capacity)
200Ah
1 to 9999Ah
Temp Comp. Coeff
(Temperature
compensation
coefficient)
-3mV/2V
0 to -9mv//2V
Rated
Voltage
Auto
Auto/12V/24V/36V/48V