21
Boost reconnect charging
Voltage
13.2V
13.2V
13.2V
9~17V
Low voltage reconnectvoltage
12.6V
12.6V
12.6V
9~17V
Under voltage
warningreconnect voltage
12.2V
12.2V
12.2V
9~17V
Under voltage warning voltage
12.0V
12.0V
12.0V
9~17V
Low voltage disconnect voltage
11.1V
11.1V
11.1V
9~17V
Discharging limit voltage
10.6V
10.6V
10.6V
9~17V
Equalize duration
120min
--
120min
0~180min
Boost duration
120min
120min
120min
10~180min
When the battery type is "USE," the battery voltage parameters follow the
following logic:
A Over Voltage Disconnect Voltage > Charging Limit Voltage Equalize
Charging Voltage Boost Charging Voltage Float Charging Voltage > Boost
Reconnect Charging Voltage.
B Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
C Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage
Discharging Limit Voltage.