6
Through the remote meter and PC software, it can realize real-time
monitoring, modification of control parameter, charge mode, load work
mode, inquiry of failure information etc.
WARNING: Connecting the controller with PC network communication
port by network cable is forbidden. It may cause the damage to the
components of the controller.
Note: Please refer to the user manual of MT, SPP-01, and PC
software for more details.
·Load Set
1Manual Control (default)
2Light ON/Off
3Light ON+ Timer
4Time Control
·Battery Type
1Gel 2Sealed(default) 3Flooded 4User
5 Protection, Troubleshooting
5.1 Protection
·PV Array Short Circuit
If PV array short circuit occurs, clear it to resume normal charge
automatically.
·Load Overload
If the load current exceeds the rated current of controller≥1.05 times
rated discharge current, the controller will disconnect the load.
Overloading must be cleared up, then pressing the switch button.