EH-TW3500/4500/5500 Disassembly and Assembly CONFIDENTIAL
SEIKO EPSON 65 Revision A
3.3.7 Removing the EX Fan (assembly)
1. Remove the Lamp. (p.55)
2. Remove the Side Cover L/Side Cover R. (p.57)
3. Remove the Upper Case (assembly). (p.59)
4. Disconnect the Power Unit Cable from the connector on the MA Board, and
disengage the two hooks of the EX Fan (assembly).
5. Disconnect the EX Fan Cable from the connector on the MA Board.
6. Remove the four screws and remove the EX Fan (assembly).
Figure 3-13.
Standard Operation Time 8 Min.
EX Fan (assembly)
C.B.P-TITE SCREW,3X10,F/ZB-3C
MA Board
EX Fan Cable
Hooks
Power Unit
Cable