6.1.2. Load Power-On Default NVR into RAM (Remote Mode) "LD" 00H 00H
[Format]
LD 00H 00H
[Function]
Loads the power-on default from a non-volatile memory into RAM, and begins using these values as the current
printer operating system settings.
This command is only available in Remote Mode.