6.1.4. Set horizontal print position (Remote Mode) FP 03H 00H 00H m1 m2
[Format]
FP 03H 00H 00H m1 m2:
[Function]
* The parameter m1 , m2 are each one byte binary data that indicate the below condition according to the
following formura.
* The unit of print start position is 1/360 inch.
(print start position) = ( ( m2 256 ) + m1 )
Horizontal Print Start Position m1 m2
Standard position 00H 00H
Borderless print position (-3.5mm) A0H FFH
Borderless print position (-2.5mm) B0H FFH
* If the parameter is out of range , this command is ignored, and the previous setting is maintained.