Disassembly And Assembly Removing the Sensors 124
Confidential
4.6 Removing the Sensors
4.6.1 CR Encoder
1. Remove the Carriage Shaft / Carriage Unit. (p.88)
2. Remove the two C.B.P. M2.6 x 5 screws that secure the CR Encoder Sensor
Board.
3. Disconnect the PW Sensor FFC from the connector on the CR Encoder Sensor
Board, and remove the CR Encoder Sensor Board.
Figure 4-156. Removing the CR Encoder Sensor Board
4.6.2 PF Encoder
1. Remove the Upper Housing / Printer Cover. (p.72)
2. Disconnect the FFC from the PF Encoder Sensor Board.
3. Remove the C.B.S. M3 x 8 screw that secures the PF Encoder Sensor Holder.
Figure 4-157. Removing the FFC and the Screw that Secures
the PF Encoder Sensor Holder
PW Sensor FFC
Connector
13) C.B.P. M2.6x5
(2±0.5 kgf.cm)
CR Encoder
Sensor Board
PF Encoder Sensor Holder
5) C.B.S. M3x8
(6±1 kgf.cm)
Connector