WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision A
Adjustment Adjustment without Using Adjustment Program 142
Confidential
5.3.1.1  PF Belt Tension Adjustment Method
1. Secure the PF Motor to the Printer Mechanism, and install the Drive Belt on the 
Gear of the PF Scale and the Pinion Gear of the PF Motor.
2. Press the [POWER] button. The LCD of the Measuring Tool displays No. 0 and 
No. 1.
3. From among No. 0 to No. 9, select the channel you want to store its setting by 
pressing the [SELECT] button. The initial value may be selected as the channel.)
4. Press the [WEIGHT] button. The initial value will be displayed. Type the ten-key 
pad so that “1.2g/m” is displayed.
5. Press the [WIDTH] button. The initial value will be displayed. Enter “5.0 mm” 
with the ten-keypad.
6. Press the [SPAN] button. The initial value will be displayed. Enter “48mm” with 
the ten-keypad.
7. Bring the Microphone as close as possible to the center of the Timing Belt.
Figure 5-9. Microphone Position
8. Press the [MEASURE] button. (“----” is displayed on the LCD screen.)
9. Put the tip of the tweezers on the Drive Belt, and flip it downward in that position. 
The “----” displayed on the LCD will become wave pattern during the 
measurement. When it has finished, the measurement result will be displayed by 
“N” (Newton) after the beep. This jig can pick up and measure sounds accurately, 
regardless of the flipping force.
10. Repeating 8 and 9, delicately shift the variable part of the PF Motor mounting 
position to adjust the tension until the tension falls within the allowable standard 
value.
Proper measurement may be interrupted by sounds picked up from 
around. Make measurement in silent environment.
Microphone of Measuring Tool
Timing Belt
As the Drive Belt is flipped with the tip of tweezers in the following 
steps, carefully choose the flipping position so that the Belt will not 
make contact with the Microphone by reaction of flipping.
A D J U S T M E N T
R E Q U I R E D
Standard Value: 10.5 ± 2N (8.5 ~ 12.5N)
 Even if the Timing Belt is flipped, the LCD screen may not 
change at all. In this case, flip the Timing Belt again after a few 
seconds have passed.
 If measurement results differ greatly from each other, acoustic 
sounds may not be picked up properly in any of the 
measurements. Therefore, flip the Timing Belt again with the 
tweezers, and record the value at which two measurement 
results are approximate. Displaying errors in the range 1/100 to 
5/100, the Measuring Tool has high reliability.
                     高速行式打印机 http://www.lineprinter.com.cn/                      
_______________________________________________________________________________________ 
_______________________________________________________________________________________ 
打印机维修论坛 http://www.printerwhy.net/     打印机驱动下载 http://www.printerwhy.com/