WorkForce 1100/Epson Stylus Office T1110/B1100/T1100/Epson ME Office 1100 Revision A
Troubleshooting Overview 41
Confidential
Table 3-11. Troubleshooting of Fatal Error
Occurrence 
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
At power-on At power-on, the CR Motor does 
not operate at all.
CR Motor 1. Check the CR Motor connector cable for damages. 1. Replace the CR Motor with a new one.
2. Check if the CR Motor operates normally. 2. Replace the CR Motor with a new one.
3. Check that the CR Motor connector cable is connected to the 
Main Board connector CN115.
3. Connect the CR Motor connector cable to the 
Main Board connector CN115.