4.3.3.2
 
Scanner Upper Housing (Artisan 700/PX700W/TX700W) 
Parts/Components need to be removed in advance: 
Scanner Unit/ADF Unit/Document Cover 
Removal procedure 
 
 
 
1.
 
Remove the screws (x7) that secure the Scanner Upper Housing. 
2.
 
Release the hooks (x3) that secure the Scanner Upper Housing. 
 
Figure 4-241. Removing the Scanner Upper Housing (1) 
3.
 
Release the ribs (x4) on the Scanner Upper Housing, and remove the Scanner 
Upper Housing in the direction of the arrow. 
 
Figure 4-242.   Removing the Scanner Upper Housing (2) 
 
 
 
 
 
 
 
 
 
 
 
 
◼
 
It is recommended to remove the Scanner Upper Housing in a 
clean room or on a clean bench to keep away from dust and dirt. 
Be careful not to damage the document glass on the Scanner 
Upper Housing. 
When installing the Scanner Upper Housing, see “ 4.2.5.1 "Scanner 