Epson Stylus Photo R280/R285/R290/Epson Artisan 50/Epson Stylus Photo T50/T59/T60/P50 Revision C
Chapter 4 Disassembly/Assembly 4.3.1 Main Board Unit (Removing Control Boards) 66
Confidential
Disassembling the Main Board Unit
1. Remove the Main Board Unit (p.64).
2. Remove the seven screws and remove the Upper Shield Plate M/B.
• Screw (6 pcs.): C.B.S. M3x6 (tightening torque: 5-7 kgf.cm) (No.1)
• Screw (1 pc.): C.P. M3x6 (tightening torque: 4-6 kgf.cm) (No.7)
(The numbers shown in the figure indicate the order of tightening the screws.)
Figure 4-21. Removing the Upper Shield Plate M/B
3. Remove the two screws and remove the Shield Plate M/B Sub.
• Screw (2 pcs.): C.B.S. M3x6 (tightening torque: 4-6 kgf.cm) (No.1)
(The numbers shown in the figure indicate the order of tightening the screws.)
4. Remove the screw and remove the Main Board Unit.
• Screw C.B.S. M3x10 (tightening torque: 4-6 kgf.cm) (No.2)
Figure 4-22. Removing the Main Board
Do not apply unnecessary force on the screw receiving parts of
the Lower Shield Plate M/B, as they are easy to deform.
When assembling or disassembling the Upper Shield Plate M/B,
be careful of its sharp edges.
Be careful of the sharp edges shown in the figure below when
assembling or reassembling.
When installing the Main Board, match the positioning hole
with the guide pin shown in Fig.4-22.
Tighten the screws in the order given in Fig.4-21 (p.66),
Fig.4-22.