Epson Stylus NX510/515/SX510W/515W/TX550W/NX415/SX410/415/TX410/419/NX215/SX210/215/TX210/213/219/ME OFFICE 510 Revision A
DISASSEMBLY/ASSEMBLY      Removing the Housing 98
Confidential
4.3  Removing the Housing
4.3.1  Paper Support Assy
 Parts/Components need to be removed in advance: None
 Removal procedure
1. Release the guide pins (x2) that secure the Paper Support Assy and remove it 
from the Upper Housing.
Figure 4-2.  Removing the Paper Support Assy
4.3.2  Stacker Assy
 Parts/Components need to be removed in advance: None
 Removal procedure
1. Open the Stacker Assy.
2. Release the Stacker Assy while pressing in the hook (x1) on the left with a 
flathead precision screwdriver or a similar tool, and remove it.
Figure 4-3.  Removing the Stacker Assy
Paper Support Assy
Guide Pins