EasyManua.ls Logo

Epson UB-E02 - 03-0011 Forced Transmission; 03-0012 Reset

Epson UB-E02
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev. A 4-9 Programming Samples
UB-E02 Technical Reference Guide
4.7.4 03-0011 Forced Transmission
Transmission is done, regardless of the flow control between the TM printer and the UB-E02.
4.7.4.1 Set-up data
4.7.4.2 Reply data
4.7.5 03-0012 Reset
4.7.5.1 Set-up data
4.7.5.2 Reply data
To reset the printer, the reset function should be enabled by a DIP switch of the printer.
The UB-E02 is also reset when the printer is reset.
After resetting, wait for approximately 10 seconds before accessing to the UB-E02, which is
the same as when turning on the power.
Off-set Size Description
14 1 Flow control
0: With flow control
1: No flow control (forced transmission)
15 2 Data length (n: maximum: 255)
17 n Data length (maximum: 255)
Off-set Size Description
14 1 Result
0: Normal
Except for 0: Failure
15 2 Data length
17 n Data string
Off-set Size Description
14 1 Reserved (undefined)
Off-set Size Description
14 1 Result
0: Normal
Except for 0: Failure

Table of Contents

Other manuals for Epson UB-E02

Related product manuals