Ergoline Vertical
User manual
Seite 6 von 29
Mains voltage
400 V / 3+N+PE / 50 Hz
Cable cross section
5 x 4mmq
Here is a copy of the label on the unit:
Model:
Ergoline Vertical
Serial number:
******
UV type:
* *
Power supply:
400V 3+N+PE 50 Hz 10kW
Year:
* * * *
Lamps:
180W 2mt
Rated current:
3x 20A
Exercise temperature:
30°C max
Service:
4 to 15 minutes
STANDARDS
The equipment is built in compliance with current standards.
Reference standards:
CEI EN 55014-1 Electromagnetic compatibility – Provision for electrical household appliances, electric
tools and the like. Part 1: Emission.
CEI EN 55014-2 Electromagnetic compatibility – Requisites for electrical household appliances,
electric tools and the like. Part 2: Immunity.
CEI EN 60335-1 General part, safety standards for electrical appliances for domestic and similar use.
CEI EN 60335-2-27 Part II, particular standard for the safety of appliances for skin treatment with
ultraviolet and infrared rays for household and similar use.
CEI EN 50106 Particular standards for routine tests on electrical appliances coming within the
application field of EN 60335-1.