25
STANDARD FIBER
NORMAL SPLICING
PREFUS TIME 0.2
PREFUSE CURR 10.0
GAP 50.0
OVERLAP 10.0
FUSION TIME 1 0.3
FUSION CURR 1 10.5
FUSION TIME 2 2.0
FUSION CURR 2 16 3
Imag
Prefusion
Cleaning
Current
ERBIUM +
M ATTENUATOR
AN SM + SM
xxxxx xx + xx
NORMAL SM +
ECCENTRIC SM + SM
ADVANCED OPERATION - Program structure overview
A
B
Program name.......................................................... 26
Certain limitations hold in splicing program names.
Fiber type .................................................................. 26
Various fiber types behave differently when spliced, so the fiber type
must be correctly specified in a splicing program.
C
Splicing process....................................................... 28
There are six different splicing processes available with the FSU 995
FA.
D
Program parameters ................................................ 36
The parameters contain the quantitative information needed to execute
the various splicing programs. They are permanantly set in the case of
the pre-defined programs, however, can be edited in the case of
Programs 11-50.
The following elements form the backbone to all FSU 995 FA
splicing programs. Each will be described in greater detail on
the indicated pages.
ADVANCED OPERATION - Program structure overview