41
Pre-defined programs: Programs 01 - 10
As explained in the section on Basic Operation, the FSU 995
FA comes with ten pre-defined programs. These programs
represent all five splicing processes, and are intended to
cover a wide array of splicing needs. It is also recommended
that you use them as a base when designing your own pro-
grams. With this in mind, the following cards list these pro-
grams’ parameters. You can also see a program’s param-
eters by following the instructions on page 13 for bringing up
the screen-viewer. Keep in mind, though, that these pro-
grams are NOT editable. So if you want to make modifica-
tions you will have to copy the program to one of the editable
slots by following the instructions in the following section.
ADVANCED OPERATION - Programs 01 - 10
Program 01
“NORMAL SM + SM”
Standard single fiber
Normal splicing
PREFUSE TIME 0.2 s
PREFUSE CURRENT 10.0 mA
GAP 50.0 mm
OVERLAP 10.0 mm
FUSION TIME 1 0.3 s
FUSION CURRENT 1 10.5 mA
FUSION TIME 2 2.0 s
FUSION CURRENT 2 16.3 mA
FUSION TIME 3 2.0 s
FUSION CURRENT 3 12.5 mA
LEFT MFD 9.8 mm
RIGHT MFD 9.8 mm
SET CENTER 255
AOA CURRENT 0.0 mA
EARLY PREFUSION NO
ALIGN ACCURACY 0.15 mm
LOSS SHIFT 0 dB
AUTO ARC CENTER NO
P01
Program 02
“DSF SM + SM”
Depressed cladding fiber
Normal splicing
PREFUSE TIME 0.2 s
PREFUSE CURRENT 10.0 mA
GAP 50.0 mm
OVERLAP 8.0 mm
FUSION TIME 1 0.3 s
FUSION CURRENT 1 10.5 mA
FUSION TIME 2 2.0 s
FUSION CURRENT 2 15.0 mA
FUSION TIME 3 2.0 s
FUSION CURRENT 3 12.5 mA
LEFT MFD 9.8 mm
RIGHT MFD 9.8 mm
SET CENTER 255
AOA CURRENT 0.0 mA
EARLY PREFUSION NO
ALIGN ACCURACY 0.15 mm
LOSS SHIFT 0 dB
AUTO ARC CENTER NO
P02
Program 03
“TITAN SM + SM”
Titanium fiber
Normal splicing
PREFUSE TIME 0.2 s
PREFUSE CURRENT 10.0 mA
GAP 50.0 mm
OVERLAP 8.0 mm
FUSION TIME 1 0.3 s
FUSION CURRENT 1 10.5 mA
FUSION TIME 2 2.0 s
FUSION CURRENT 2 14.0 mA
FUSION TIME 3 2.0 s
FUSION CURRENT 3 13.0 mA
LEFT MFD 9.0 mm
RIGHT MFD 9.0 mm
SET CENTER 255
AOA CURRENT 6.5 mA
EARLY PREFUSION YES
ALIGN ACCURACY NO
LOSS SHIFT 0 dB
AUTO ARC CENTER NO
P03
Program 04
“NORMAL MM + MM”
Multimode fiber
Normal splicing
PREFUSE TIME 0.3 s
PREFUSE CURRENT 11.5 mA
GAP 50.0 mm
OVERLAP 12.0 mm
FUSION TIME 1 0.3 s
FUSION CURRENT 1 12.0 mA
FUSION TIME 2 2.0 s
FUSION CURRENT 2 15.5 mA
FUSION TIME 3 1.0 s
FUSION CURRENT 3 12.5 mA
LEFT MFD 9.8 mm
RIGHT MFD 9.8 mm
SET CENTER 255
AOA CURRENT 0.0 mA
EARLY PREFUSION NO
ALIGN ACCURACY 0.25 mm
LOSS SHIFT 0 dB
AUTO ARC CENTER NO
P04