EasyManua.ls Logo

Ericsson FSU 995 F - Index

Ericsson FSU 995 F
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80
Index
A
Acceptable offset 29, 37, 38
Align accuracy 40, 56
Alignment
fine 17, 19
rough 18
Altitude, compensation for 61, 64
AOA current 40, 56
Arrow buttons 7, 18, 47
Attenuator making. See Splicing
processes: attenuator making
Automatic arc re-centering 40, 56
Automode 12, 14
Autoxct offset 55, 56, 62
AUX-connector 74
B
Base line tilting 60
Battery 8
charging 66
checking voltage 66
low level warning 66
Binary parameter values 54
Buttons (overview) 7
C
Carrying case 5, 6
Character selection 47. See also
Quick character selection
Cleaning
electrodes 68
fiber clamps 67
fiber during preparation 10
V-grooves 10, 67
Cleave angle. See Gap angle
Cleaving 11
cleaving lengths 11
Cold image 21
Control parameters 37, 49
Core 22
eccentricity 22, 28, 29, 37, 38
CPU settings 62
Current test 57
D
Date/time 62
Desired attentuation 34, 38
Display gap angle 61, 63
E
Early prefusion 40, 56
ECF factor 30, 34, 38
Electrode brush 6
Electrode warning 62
Electrodes 6
changing 69
cleaning program 5, 58, 68
maintenance 5, 68
safety 5
Enter button 53
Erbium splicing. See Splicing
processes: erbium splicing
Escape button 7
External monitor 74
F
Fault messages 17, 71
Faults, observable 73
Fiber clamps 6, 12, 23
maintenance 67
Fiber fixtures 6, 23
Fiber insertion 12
Fiber preparation 10
defects 13
Fiber types 26, 36, 48
depressed cladding 27
dispersion shifted 27
erbium 26
invisible core 27
multimode 26
silica core 27
Focusing monitor 7
Fuse button 7, 17, 20
Fuses 7
replacing 66
Fusion current parameters 39
Fusion time parameters 39
G
Gap 39
Gap angle 63
Gap button 7, 19
Gap close intensity 30, 38
Global parameters 61
Global xct 55, 62
H
Heat oven 6, 23
Heat-shrinkable sleeve 10, 23
Hot core alignment. See Splicing
processes: hot core alignment
Hot fiber index profile 31
Hot images 4, 21, 22, 60
button 7
Humidity 5
I
Index limit 31, 33, 37
Using the ... 33
Index profile. See Hot fiber index
profile
K
Key number. See Security
L
Language, changing 61
Left MFD 34, 40, 55
Light intensity curves 60
Loss estimation level 62
Loss factor 31, 37
Loss shift 40, 56
M
Macrobending 62
Maintenance 5, 66
battery 66
electrodes 68
fiber clamps 67
fuses 66
mirror one 70
time table 70
V-grooves 67
Manual mode 14
Matchsticking 27. See also Splic-
ing defects
Max eccentricity 29, 37, 38
Max gap angle 61
Max view angle 61
Message field 7, 43
Index