Radio Terminals
4.2 Modem Unit (MMU)
4.2.1 Overview
The MMU is the indoor part of the Radio Terminal and determines the traffic
capacity and modulation. It is available in the following types:
MMU2 B
A traffic capacity agile plug-in unit for C-QPSK
modulation, used for the following traffic capacities in
Mbit/s:
2xE1, 4xE1, 8xE1, 17xE1
MMU2 C
A traffic capacity and modulation agile plug-in unit,
used for the following modulation schemes and traffic
capacities in Mbit/s:
C-QPSK: 2xE1, 4xE1, 8xE1, 17xE1
16 QAM: 8xE1, 17xE1, 32xE1
MMU2 D
A traffic capacity and modulation agile plug-in unit,
used for the following modulation schemes and traffic
capacities:
16 QAM: 22xE1, 46xE1
128 QAM: 35xE1, 75xE1
MMU2 E 155
A high capacity SDH plug-in unit, used for the following
modulation schemes and traffic capacities:
16 QAM: STM-1 + 1xE1
64 QAM: STM-1 + 1xE1
128 QAM: STM-1 + 1xE1
MMU2 F 155
A high capacity SDH plug-in unit with XPIC support,
see Section 4.2.2.11 on page 78, used for the following
modulation schemes and traffic capacities in Mbit/s.
XPIC is only used in combination with 128 QAM, if not
used MMU2 F 155 has the same modulation schemes
and traffic capacities as MMU2 E 155:
16 QAM: STM-1 + 1xE1
64 QAM: STM-1 + 1xE1
128 QAM: STM-1 + 1xE1