11
Input &
GND Fuse Size
Conductor* Amps
CU/AWG
208 64 No. 6 90
220 61 No. 6 80
230 58 No. 6 80
482cc 400 33 No. 10 40
460 29 No. 10 40
575 23 No. 12 30
208 82 No. 4 120
220 77 No. 4 120
230 74 No. 4 120
582cc 400 43 No. 8 70
460 37 No. 8 60
575 30 No. 10 50
* Sized per National Code for 75
o
C rated copper conductors @ 40
o
C
Not more than three conductors in a raceway or cable. Local codes
should be
f
ollowed i
f
they speci
f
y sizes other than those listed above.
Rated Input
100% Duty Cycle Rating
Volts Am ps
Figure 2.1 Connecting Primary Power Leads
Table 2.1 Recommended Input Conductor Size and
Line Fuses
Figure 2.2 Input Terminal Board
* Double Link Provided
( ) Connections for 50 Hz
230/460 (220/400)V illustrated with voltage links in
the factory supplied 460 volt configuration.
SECTION 2 INSTALLATION
453CC
553CC
Strain Relief
Rear Panel (Inside View)
TB3 Located on
Fan Bracket
Recommended Cable Strip Lengths
Ground Fault
Switch*
SWITCH
GROUND LUG
NUT
HORSESHOE
5"