S0740 800 210/E101102/P18
- 4 -
ck10_00
TECHNICAL DATA
COOL 1
Power consumption 24V DC / 2A
Cooling power 1.3 kW (Rating at 40 K and 1 l/min)
Equivalent continuous A-weighted
sound pressure level
< 70 dB (A)
Coolant Ready mixed (50% water and 50% mono-ethylene glycol)
Coolant quantity 4.5 l
Maximum flow 2.0 l/min
Maximum pressure 4 bar
Operating temperature -10° to +40°C
Transportation temperature -20° to +55°C
Dimensions lxwxh 610 x 256 x 256 mm
Weight empty 12 kg
Enclosure class IP23
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP23 is designed for indoor and outdoor use.
WIRING DIAGRAM
Component description
Component Description
5 Cooling unit
5AP1 Circuit board with control electronics
5M1 Pump with motor, 24V DC
5S1 Coolant pressure switch (enclosed in pump 5M1)
5EV1 Cooling fan, 24V DC
5SL1 Flow guard. Monitoring coolant flow (option)
5XP.. Plug connector (Pin)
5XS.. Socket connector (Sleeve)
5XT.. Terminal block