22
4. TR-23A Truck Kit, P/N 36224. Provides complete mobility for power
source. Includes handle, 4 castors and gas cylinder bracket.
5. AC/DC Digital Meter Kit with Current Preset, P/N 36226 (Optional
for Heliarc 252; installed in Heliarc 352). This meter kit provides direct
accurate reading of AC and DC open-circuit and welding voltages as well
as welding current. The kit mounts directly to the front of the power source.
A plugged hole in the front panel of the unit provides access for the meter.
Allows pre-set of welding current.
6. WC-8C Coolant Circulator, P/N 33739. A self contained 1.5 gallon ca-
pacity water cooler suitable for most water cooled torch applications. The
unit circulates 1 gallon per minute at 60 psi and operates from 115 volt,
60 Hz., 1 phase (5.4 amp) input. The circulator fits in place of cylinder in
the TR-23 Truck.
7. Current (Slope) Control Module, with Trigger Lock, P/N 36228. Allows
setting of start (initial) current, up-slope time, down-slope time, and final
current, as well as standard or latching torch trigger.
NOTE: When using pulse and/or slope control, dip switch settings on main
control board must be reset, see 4.1.6 in the Maintenance section.
8. Pulse Control Kit, P/N 36227. Allows independent setting of Peak Current
(I1), Peak Time (T1), Background Current (I2), Background Time (T2). Has
a three position switch for setting Peak (I1), Background (I2) and Pulse
modes.
9. Power Factor Kit, P/N 36220. This kit when installed in power source will
reduce input current draw at least 20%. It consists of 3 prewired power
factor capacitors that installs easily inside the power source.
SECTION 2 INSTALLATION