Malfunction Display
Should a malfunction occur, the display shown in figure 16
will appear, even if the unit is in ‘standby mode. The
display will show an error cost and a description. For error
codes, please refer to the table below:
Factory Setting
Fig.
Description and content:
Setting range /option
Default
value
Remark
1
Stand-by
status: Outlet water temperature:
/
/
Actual tested value,not adjustable
Stand-
by status:Target/setting water tempertaure
10~60
°
C
55
°
C
Adjustable
2
Running status: Outlet water temperature
/
/
Actual tested value,not adjustable
Running status:Target /setting water temperatur
e
/
/
Actual tested value,not adjustable
3
available functions:Main
as
select
option
/
/
4
main menu: Mode select/Unit status
as
select
option
/
/
5
Mode select :
as
select
option
/
/
Aux heating
on/off
off
Adjustable
Fan mode
on/off
off
Adjustable
6
Unit status
Tank
top
temperature.
/
Actual tested value,not adjustable
Tank
bottom
temperature
/
Actual tested value,not adjustable
Pipe
temperature
/
Actual tested value,not adjustable
Evaporator
temperature
/
Actual tested value,not adjustable
Ambient
temperature
/
Actual tested value,not adjustable
Swell
valve
/
Actual tested value,not adjustable
7
Parameter
1.0
Operation
1.1
Out
water
10~60
°
C
55
°
C
Adjustable
1.2
T1(heating)
2~15
°
C
5
°
C
Adjustable
2.0
Aux
heaitng
2.1
Start
temperature
30~90
°
C
55
°
C
Adjustable
2.2
Start
delay
0~90
*5min
40
*5min
Adjustable
3.0
Defrost
3.1
Defrost
cycle
30~90
minute
45minute
Adjustable
3.2
Defrost
in
temperature
-30~
0
°
C
-7
°
C
Adjustable
3.3
Defrost
out
temperature
2~30
°
C
13
°
C
Adjustable
3.4
Max
time
1~12
Minute
8
Minute
Adjustable
4.0
Save
4.1
Power
save
0(NO)/1(YES)
1(YES)
Adjustable
5.0
Disinfection
5.1
Target
temperature
30~70
°
C
65
°
C
Adjustable
5.2
Maintain
time
0~90Minute
30Minute
Adjustable
6.0
Swell
valve
6.1
Mode
Auto/Manual
Auto
Adjustable
6.2
Over
heat
-20~20
°
C
5
°
C
Adjustable
6.3
Adjust
step
100~500
N
350
N
Adjustable
8
Maintenance
See above table
Actual running record, not adjustable
9
Timer
Date
/
/
Adjustable
Clock
/
/
Adjustable
Timer
1
on
(YES)/
×
(NO)
×
(NO)
Adjustable
Timer
1
off
(YES)/
×
(NO)
×
(NO)
Adjustable
Timer
2
on
(YES)/
×
(NO)
×
(NO)
Adjustable
Timer
2
off
(YES)/
×
(NO)
×
(NO)
Adjustable