MINIMUM OPERATIONS TO VERIFY PROPER INSTALLATION Page 15
MINIMUM OPERATIONS TO VERIFY
PROPER INSTALLATION
1. PROGRAMMING
Access to programming: lift the local telephone handset and dial
.
The programming activated message will be heard.
Program a telephone number for the emergency-call alarm:
dial
<telephone number> .
Record the identification message of the specific elevator, which is
meant to contain all necessary information concerning the elevator
location: dial
and, after the “Correct” message, pronounce
the message and hang up.
To listen again to the previous message: lift the handset and dial
.
Make an external call to check the PSTN line or the universal gateway is
properly working: dial
and digit the telephone number to make a test
call.
2. TESTING THE ALARM PROCEDURE
Press the emergency call button for more than 3 seconds (factory
value).
The alarm starts.
3. ANSWERING THE ALARM
Note: the activation mode of the communication with the trapped
person can be configured with the “Two-way communication
mode during an alarm” programming (code 78).
-1
st
mode: automatic two-way communication established after messages
(factory default)
Answer by the called party.
The two-way communication mode will be activated after the voice messages.
Speak with the trapped person.