7. Delivery, installation and start-up
7.1 Delivery and transport
The devices are delivered mounted to a Europallet or a one-way pallet. The
devices are wound in stretch wrap to prevent scratches and transport damage.
Please dispose of the packing material according to local regulations.
Upon delivery, please inspect the device for transportation damage.
Detected damage must be documented and reported immediately.
ESTA customer service: +49 (0) 7307 804 - 0
When setting up the device, make sure the ground can support it.
The devices are delivered without a switching device. The operator of the device
must properly determine that the device can be safely connected to the electrical
source and operated. The motor must be electrically secured against overload.
Operating the device without such protection voids the motor warranty. It is
recommended that a motor safety switch be used, with which the device can be
turned on or off immediately.
Installation work must be performed only by an electrical specialist or by a
person trained for the purpose!
Before setting up the cable connection between the device and the power
grid, check to make sure the operating voltage shown on the model plate is
the same as that of the grid.
Plugs and connectors complying with EN 61241-14 must be used for
connecting electrically driven industrial exhausts and dust extractors.
Coupling plugs and connectors or adapters are not permitted.
The device must be set up so that the dust collection drawer and tapping device
are accessible. When connecting a suction hose, make sure to use only
electrically conductive hoses and that the electrical connection between the hose
and the port is perfect. If a so-called “spiral hose” is used, the metal spirals must
be stripped and pressed to the bare wall of the exhaust port with a pipe clamp
after the hose is attached.