ETC Installation Guide
F-Drive B-Box4
F-Drive B-Box4 Page 3 of 11 ETC
F-Drive Model
B-Box Models
FD-BBOX-4R FD-BBOX-4M FD-BBOX-4T
F-Drive R12 with
CC-150Card
Four RJ45 outputs for
four F-Drive-compatible
luminaires with RJ45
connectors, one per
channel. For a list of
compatible luminaires,
see
F-Drive-Compatible
Luminaires with RJ45
Connectors on page1
.
Four Molex Mini-Fit
outputs for four
ArcSystem Pro
luminaires, one per
channel. For a list of
compatible luminaires,
see
F-Drive-Compatible
Luminaires with Molex
Connectors on page1
.
Four two-pin terminal
outputs for third-party
constant current loads.*
F-Drive W1CCDriver
F-Drive R12 with
FTW-150Card
Four RJ45 outputs for
four ArcSystem Navis
100 Fade to Warm
luminaires, one per
channel.
F-Drive
W1FadetoWarmDriver
*Total number of loads and number of loads per channel depends on the specifications of the third-party
loads. Visit the F-Drive System Design Tool at etcconnect.com/FDriveSysDesignTool to learn more, and
search the LEDDimming Compatibility Database at etcconnect.com/compatibility to see if your load is
compatible. If your load is not in the compatibility database, follow the instructions at the link above to
contact the ETC Applications Engineering department to arrange for compatibility testing.
Note:
Each of the four output channels of an R12 CC-150Card or W1CCDriver can be
configured independently to provide 200700 mA drive current. See Configure the
Output Current on page11 and the
F-Drive Series R12 Installation Manual
or
F-Drive
Series W1 Installation Manual
for information on configuring the output current.
CAUTION: To avoid damage to equipment, use FD-BBOX-4M to connect
ArcSystem Pro One-Cell luminaires to your F-Drive Driver.
If you do not use FD-BBOX-4M, you must use the proper pinouts for each model
of ArcSystem Pro One-Cell luminaire. See the F-Drive Series R12 Installation
Manual or F-Drive Series W1 Installation Manual Appendix A, section "Connect
ArcSystem Pro One-Cell Luminaires to the Terminal Block Output."
Connect F-Drive-Compatible Luminaires with an FD-BBOX-4R
Connect up to four F-Drive-compatible luminaires with RJ45 connectors to an F-Drive with a
FD-BBOX-4R. Visit the F-Drive System Design Tool at etcconnect.com/FDriveSysDesignTool to learn
more.
Note:
Navis RGBW luminaires are not compatible with B-Box4.
Note:
If you install a B-Box within an Emergency Lighting Circuit, follow NECmarking
requirements or local jurisdiction requirements.