-6-
IV Technical Specifications
Function
Measurement of AC leakage current, AC
current and on-line measurement
Power Zn-Mn dry battery,6F22,9V
Test Mode Clip-on CT,integral mode
Display Mode Four digits LCD display
Dimension
Width × Height× Thickness:
175mm×70mm×38mm
LCD Dimension
35mm×21.5mm;display domain:32mm×15mm
Sampling Rate about 2 times/s
Frequency 50/60Hz Automatically
Range Shift Automatically
0.00~60.00A: ±1.5%±5dgt
60.00A~199.9A: ±2%±5dgt
200.0A~300.0A: ±4%±5dgt
Accuracy
(23 ±3,℃℃
below 70%RH)
300.0A~600A: ±4%±5dgt
Voltage Range
AC600V
RS232 Interface
Data stored in the memory of the meter via
RS232 upload to PC, or on-line monitoring
Storage
99units,all used when display FULL