14• MAINTENANCE SCHEDULE
BPHP2 - BPHPX2
IMPORTANT : The warranty will only apply if your mower has had the service carried out by your dealer, after the first 20 hours.
After the first 10 hours or before starting, if the belt has been installed for more than 3 months, have your dealer tension the blade transmission
toothed belt.
Parts Before each use
After the first
20 hours
Every 125
hours
Every 250
hours
Every 500
hours
Every 1000
hours
Every 2500
hours
CHECK
Engine oil level
HAVE THE SERVICE DONE BY YOUR DEALER
AFTER THE FIRST 20 HOURS
Hydraulic oil level
Coolant level
Control parts
Battery level
Top up if
necessary
Cutting unit
Condition &
tightness, sharpen or
change if necessary
Blade transmission toothed
belt
Conditions
and tension
Blade transmission Vee-belt
Alternator belt and feed
transmission
Electromagnetic clutch
Breaking
time
Wheels Check pressure
Steering
Tightness of
the ball joints
Electrical circuit
Correct functioning
of the safety devices
Transmission
Correct functioning
of pedals
CLEAN
Engine hood grille and
inspection trap
Several times during
each use
Removal radiator grille
Several times during
each use
Radiator and pre-filter
Air pre-filter
Engine air filter
Hydraulic components
CHANGE
Training of prefilter /fuel
water
Engine oil
Hydraulic oil
Angular gear oil
Diesel tank or once a year
Cooling liquid
or every 2 years