9 | 12
dimensions up to 5x6 mm
2
use the tighter rubber seal.
For the cables with dimension of 5x10 mm
2
and 5x16
mm
2
use a looser rubber seal which should be already
inside the gland by default.
You can change the rubber seal with removal of the
gland plastic top (unscrew it) and by simply pushing the
rubber seal out of the gland. After that the new rubber
seal is inserted into the cable gland.
Wires preparation
Proceed with preparation of cables. Prepare power
supply cables from which cable jacket needs to be
removed. Around 15 cm should be removed so that the
wires lengths are sufficient to connect them to the
elements inside the charging station.
You can now pull the power supply cable through the
gland. About 17 cm of power supply cable should be
pulled to the other side of the gland. About 2 cm of cable
jackets should be pulled through the cable gland as well.
This will make cable manipulations inside the charging
station easier and it will completely seal the gland. Make
sure that the cable is fastened securely with the gland so
that it cannot be pulled out. You can tighten the gland by
turning the plastic gland top in clockwise direction.
Strip the wires of insulation using special pliers and
attach cable ferrules on the end of the wires, and a cable
ring for grounding wire.
When Ethernet method is used for physical connectivity
for communication purposes, prepare the Ethernet UTP
cable in the same manner. Your first step should be to
remove the gland filler which is part of the UTP gland
rubber. You can simply push the filler out after you
remove the gland cap by unscrewing it in counter-
clockwise direction. Insert the rubber back into the gland
as it will likely come out together with the filler.