Operating Instructions
Evaluation Unit CMS-E-ER
10
Subject to technical modifications; no responsibility is accepted for the accuracy of this information. © EUCHNER GmbH + Co. KG 2102344-11-10/20 (Translation of the original operating instructions)
Wiring diagram for > 2 up to 30 read heads CMS-R-…
BN WH BU BK
Lesekopf 1/
Read Head 1
BN WH BU BK
Lesekopf 2/
Read Head 2
BN WH BU BK
Lesekopf 3/
Read Head 3
BN WH BU BK
Lesekopf n/
Read Head n
H12H73H11 H74H22
2...30 Leseköpfe / 2...30 Read Heads
Wiring diagram for > 2 up to 10 read heads CMS-RH-…
gn
BKBU
-
PK WHBN
+
GY
NC
Lesekopf 1/
Read Head 1
H12H73H11 H74H22
2...10 Leseköpfe / 2...10 Read Heads
gn
BKBU
-
PK WHBN
+
GY
NC
Lesekopf 2/
Read Head 2
gn
BKBU
-
PK WHBN
+
GY
NC
Lesekopf n/
Read Head n
...
...
Wiring diagram for CMS-E-ER
Leseköpfe/
Read Heads
Y2 Y3
13
14
Rückführkreis/
Feedback Loop
23
24
Sicherheits-
Kontakte
Hilfs-
kontakte
31
32
-K1
H12 H73H11
0V
A2
UB
A1 H74 H22
Y1
CMS
The following applies to all the illustrations:
f Evaluation unit electrically isolated
f Actuator not in the actuating range
Figure 3: Wiring diagram for CMS-E-ER, part 2