TEMP CONTROL/GENERAL OPERATION
The fridge is designed to either refrigerate or freeze food. The unit is suitable for outdoor
use, such as camping and tailgating.
The fridge is designed to operate in ambient temperatures between 50° F and 110 °F, in
humidity up to 90%, and can operate continuously at an angle of 30° maximum.
If you wish to refrigerate medicines, first check to ensure the fridge’s cooling capacity
meets the required temperatures for the respective medicines.
Note:
Effective operation of the appliance requires heat to be radiated away from the condenser
located at the end of the cabinet.
There must be adequate airflow around the compressor at all times.
The cooling system has been designed to operate correctly when the appliance is positioned
on an incline of up to 30 degrees. It is recommended that you run the unit on an incline of
more than 30 degrees for no more than four (4) hours at a time.
Battery protection can be set by pressing and holding "SET" for three seconds.
BATTERY MONITOR SETTING
09
12V DC input
LOW
MEDIUM
Cut out
Cut in
8.5 V
10.9 V
10.1 V
11.4 V
11.1 V
12.4 V
HIGH
24V DC input
LOW
MEDIUM
Cut out
Cut in
21.3 V
22.7 V
22.3 V
23.7 V
24.3 V
25.7 V
HIGH
*Values are for reference only and may be subject to change depending on conditions
and power supply.